Regards John rogerluethy / April 26, 2013 You're welcome ! This state can occur when a relationship was in the Consistent (Synchronized) state and experiences an error that forces a freeze of the consistency group. If anything is ok you can then clean your SVC error log. And we do not have setup consistent group. Source

About your second question, you need to check your cluster looking for any node or missing I/O group. You may try in the CLI svcinfo lssystemstats -nohdr -history cpu_pc to get some Perf History Please see also ->http://aussiestorageblog.wordpress.com/2012/06/22/storwize-v7000-and-svc-performance-monitoring/ -Roger Reply Johnny / October 1, 2013 Hi We help customer do you have any method to do that ? The IBM Storage group is no longer active.

Svc Error Codes

Mickey Baker replied Nov 11, 2015 It appears that you have lost one of the following: Fibre channel port on the SVC; Fibre channel port on your storage controller; Fibre channel mkaria replied Nov 10, 2015 Mikey, Thank you for your reply! You're now being signed in. No spaces please The Profile Name is already in use Password Notify me of new activity in this group: Real Time Daily Never Keep me informed of the latest: White Papers

mkaria replied Nov 13, 2015 I am going to login to the SVC web page and see if I can gather some additional information on what may be causing the error. However is there a way I can determine whether the primary and secondary volumes are consistant over a period of time after the I/O stops on primary. Background is 1920 error intermittently. V3700 Error Code 2030 I'm now using the HP MPIO manager (it is a snap-in in Storage / Device Manager) where you can see all your paths state in the GUI.

And then we have to start the Global Mirroring again. Svc Error Code 2030 I got a DS3300 but I dont have the storage manager. I did get the alert on 11/9/15 and today - 11/10/15. http://www.ibm.com/support/docview.wss?uid=ssg1S1004018 We have a global mirror configured between two sites, We are planning to shutdown the host connected to primary and breaks the global mirror after some time .Is it possible to

the delay may be disappear, right? V7000 Troubleshooting, Recovery And Maintenance Guide b)Error code 1220: Remote FC port has been excluded & c) Error code 1335: Quorum disk not available. kumar Reply rogerluethy / November 30, 2013 Hi Kumar 10% packet loss is way to high. I am located in Toledo, Ohio.

Svc Error Code 2030

There are likely FOUR paths between the two devices - at least one has failed. My questions are: 1) What are the possible causes of these errors & how do I prevent them?? 2) For the quorom disks, all three with indexes 0, 1 & 2 Svc Error Codes Did you try the Redbook ->http://www.redbooks.ibm.com/redbooks/pdfs/sg247065.pdf ? Node Warmstarted Due To An Internal Error I am aware of at least 2 situations where that appears to have happened but have so far been unable to find any threads out there.

In the Management Console go to "Monitoring" and then "Performance" there you can see the CPU load. -Roger Reply John / September 17, 2013 Thanks Roger , I saw that in http://colvertgroup.com/error-code/imagistics-error-code-h5-01.php I will bring this information to our Development. -Roger Reply Brian Beeler / March 5, 2013 Roger - it's come to our attention today via Seagate's blog that you used our But I doubt it, it looks like this happened almost a month ago. (What? This may be a one time anomaly that won't recur, or your entire storage system might go down tomorrow. Managed Disk Error Count Warning Threshold Met V7000

One last thing regarding replication , while we are doing the activity we will stop the mirror and some activity will be performed at Site A (primary) . Very best regards Shortie Reply John / April 26, 2013 Hi Roger, I have a query regarding IBM SVC Global mirror . Search this Blog Search for: Follow me on Twitter Decisions.. have a peek here May be this is because there might be write i/o happening in primary.

is there any way I can do to improve ?. Error Sans Nice ! Toolbox.com is not affiliated with or endorsed by any company listed at this site.

Reply rogerluethy / October 17, 2013 Yes try to do that also.

Michelle Top Best Answer 2 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... Reply rogerluethy / April 26, 2013 John, Sorry i'm a CLI guy. Thanks for advice Jimmy Chien Reply rogerluethy / October 17, 2013 Hi Jimmy At the end of the day it comes down to this. You may have an intermittent cable issue.

Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... Thanks for the previous help and advises. I am learning as I go. http://colvertgroup.com/error-code/ie-error-code-12221.php Nagios Support Forum Support for Nagios products and services Skip to content Advanced search Board index Change font size FAQ Register Login The board requires you to be registered and logged

Basically when trying to check with tperf it reports very huge RTT values in medium priority, where as ping reports 30-40ms , but with these many packet loss. We found 1630 and 1720. You might have issues with a FC switch. No real time monitoring software?) Sorry I can't be any more help.

PCMag Digital Group AdChoices unused Log In E-mail or User ID Password Keep me signed in Recover Password Create an Account Blogs Discussions CHOOSE A TOPIC Business Intelligence C Languages Did I understand right? Thank you ! White Papers & Webcasts Using Virtualization to Balance Work with TCO Lab Validation Report: IBM Tivoli Storage manager for Virtual Environments Reducing the Complexity of Your Storage Environment Simplify and consolidate

Hope this helps Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... Regards, Roger Reply John / September 15, 2013 Thanks Roger , In CLI which command you mean . Reply rogerluethy / October 2, 2013 You're welcome🙂 John Mathew / October 4, 2013 Hi Roger, I have a query regarding performance of SVC, how much will be the idle read The IBM Storage group is no longer active. 3210364 Related Discussions Number of Device Paths Has Reduced/Device Logins Reduced DS4800 SDD and SVC vpaths Fibre Link Issue SVC multipathing IBM SVC

Please contact them and open up a ticket. -Roger Reply Nikola / May 11, 2015 Hi, my name is Nikola. Read more here: http://www-01.ibm.com/support/docview.wss?uid=ssg1S1005069 If anybody has some info how to solve this situation (without rebooting nodes) I would appreciate it. Reply rogerluethy / April 26, 2013 Hi John If I/O operations on the primary volume are paused for a small length of time, the secondary volume can become an exact match Thanks a lot -Roger Reply Alex / March 26, 2014 HI, my name is Alex.

Watch this Thread Sign in or post as a guest: E-mail or User ID Password Recover password Submitting... 5828398 Related Discussions SVC errors? The request cannot be fulfilled by the server The request cannot be fulfilled by the server United States English English IBM® Site map IBM IBM Support Check here to start