Home > Informix Error > Informix Error 08001

Informix Error 08001

Contents

If not then maybe you cannot go through firewall or other network device. What do you see instead? Thanks! 15415Views Categories: Data Sources & Connections Tags: none (add) This content has been marked as final. My user can connect to the data source via MS Access, just not Tableau Desktop.My user that is having the connection problem sent me a file that sort of reminds me weblink

more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed Jilleneh) Hi Jilleneh,If this is the first time you are trying to connect, make sure that your server, network, firewall are all ok. This jar is returning an error code on exception using the "exit(errorCode)" command. Note: When using Windows Sockets, if the is WSAStartup, and is 0, then contains the Windows Sockets Specification version level requested by DB2, and contains the Windows navigate to this website

Protocol Specific Error Code(s): "*", "*", "0". Sqlstate=08001

Re: IBM DB2 Connection Error Message Toby Erkson Jan 14, 2015 9:51 AM (in response to Toby Erkson) Huh...I can't remember what became of this but we have no issues. This would help us to collect more diagnostic details and expedite recommendations for the problems you have reported. Re: Visual Stuido 2012 & IBM IDS 10.0 & IBM Addon for VS 2012 Mon, 2013-03-04 17:22 Hi, 1) Since you have mentioned IDS 10.0, would like to re-iterate that you Show: 10 25 50 100 items per page Previous Next Feed for this topic The request cannot be fulfilled by the server Skip to content Ignore Learn more Please note

  1. How to DM a no-equipment start when one character needs something specific?
  2. Original comment by [email protected] on 24 Apr 2014 at 3:57 GoogleCodeExporter commented Mar 16, 2015 onsoctcp is not supported, they need to move to DRDA only.
  3. Try configure it with ODBC manager.
  4. Are non-english speakers better protected from (international) Phishing?
  5. Browse other questions tagged .net-4.0 informix or ask your own question.
  6. MQ The format of the ID is the MQ queue name.
  7. Re: IBM DB2 Connection Error Message guest contributor Aug 15, 2011 10:50 AM (in response to .

Communic ation protocol being used: "TCP/IP". Location where the error was detected: "10.25.0.34". Find and display best Poker hand Why don't we have helicopter airlines? The database manager configuration file at the server is configured with the proper communication related parameters.

In tape parameter the information is as below, please advise me how to take the logical log without tape: Tape Device [/dev/rStp0 ] Block Size 20 Kbytes Tape Size 2000000 Kbytes SQLSTATE=08001Unable to connect to the server. Related 2Connection string for Informix for .NET3How do I connect to Informix with .NET?2Connecting to Informix using .NET1Why can't I update TEXT type columns in Informix2Informix “Invalid Argument” exception with connection navigate to these guys Location where the error was detected: "fe80::1:10 9:c212:ce44%10".

This is the accepted answer. Like Show 0 Likes(0) Actions Go to original post Actions Remove from profile Feature on your profile More Like This Retrieving data ... If you get a message like "telnet is not recognized as an internal or external command ..." then telnet is not installed on your machine. If present, contains the global errno value from the CPI-C function call. is not applicable.

Python Informix Connect

Incoming Links Re: AS400 to Tableau För att kunna använda diskussioner i Google Grupper måste du aktivera JavaScript i webbläsarinställningarna och sedan uppdatera sidan. . https://github.com/ibmdb/python-ibmdb/issues/116 Migrating Informix external routines to DB2 Mon, 2013-02-18 15:11 We have Informix external routines such as alter_java_path, blobexport, etc., that are called by Informix stored procedures. Protocol Specific Error Code(s): "*", "*", "0". Sqlstate=08001 If you have fast database servers, it's a great experience!This error usually occurs when accessing a new database or server for the first time, and indicates that part of the setup Python Ibm_db Explanation: An error has been detected by the communication subsystem.

Already have an account? http://colvertgroup.com/informix-error/informix-error-309.php Also, do I need both those lines if, as you suggest, I only connect using port 9091? Hit a curb; chewed up rim and took a chunk out of tire. sqlcode : -30081 sqlstate : 08001 Like Show 0 Likes(0) Actions 7.

This could be caused by one of the following: The database agent at the server was forced off by the system administrator. The communication subsystem at the client node or server node has not been configured correctly, or has not been started successfully. Reload to refresh your session. check over here re-installed only the client SDK and it worked.

I am going to try and access DB2 tables this week. If you just get a blank screen, it means that you have made a successful network connection, and the problem lies elsewhere - probably in the database drivers.7. But now another question: We have other applications accessing this database server via onsoctcp.

The real issue is here: the Informix server that I wish to connect to (which is on a different network entirely) is available for me to connect only via the onsoctcp

Protocol specific error code(s): "", "", "0". Related 3How do I connect to Informix with .NET?3Cannot connect to Informix from ASP.NET application1Error connecting to Informix using .NET driver2Informix .NET Connection String0Connecting to Informix DB from Linux - client Can a GM prohibit players from using external reference materials (like PHB) during play? Regards, Raj Visual Stuido 2012 & IBM IDS 10.0 & IBM Addon for VS 2012 Mon, 2013-03-04 10:50 When i try create database connection in Server Explorer in VS 2012 and

I don't think any form of SQL will work because the server has no knowledge of which client is connecting to it, right? Communication function detecting the error: "recv". Hot Network Questions Keyboard shortcut to search for text in MS Outlook 2007 dired - sort and hide by default Lunacy - what does it mean? this content The communication subsystem at the SOCKS server, if one is being used, has not been configured correctly, or has not been started successfully.

The connection will not work and the error thrown is: ERROR [08001] [IBM] SQL30081N A communication err or has been detected. My guess was that this shouldn't matter too much since I know the Informix version and host, port, username, etc. Thanks in advance. .net informix ibm provider share|improve this question edited May 30 '12 at 12:14 Uwe Keim 22.6k25100159 asked May 30 '12 at 9:49 James Gatt 53111 add a comment| APPC The format of the ID is the fully qualified LU name (networkID.LUname).

As pvdg42 suggested, you can try IBM support to resolve this issue. How to give player the ability to toggle visibility of the wall? I'm using an ASP.NET application and realize that in some cases a lock is unavoidable, but would like to record both the table and the lock owner, not just the table. If you just get a blank screen, it means that you have made a successful network connection, and the problem lies elsewhere - probably in the database drivers. 7.

The web site worked fine with the dll from the 32bit installation. NETBIOS contains the return code from the call to NetBIOS. and are not applicable. Any suggestions on how to achieve this? Topic Forum Directory >‎ Information Management >‎ Forum: .NET Development with DB2 and IDS >‎ Topic: ERROR [08001] [IBM] SQL30081N - Connection error when using DB2 Server Client with Informix,… 2

Open a command window within Windows. Interestingly enough there are 2 scenarios in which one the connection string works and one which does not. Substitute the first parameter with the IP address or name of your server. This is compiled using version 3.50 of the Informix tools.

At the command prompt, run a "telnet" command like either of the following: > telnet 192.168.1.1 50000 > telnet mydatabaseserver 50011 4. more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed One or more of the communication protocols specified by DB2COMM may not have been successfully started. A database agent could not be started at the server because the maxagents database manager configuration parameter has been exceeded.

I still get the same error as described above.DB2 database error 0x80004005: SQL30081N A communication error has been detected.