Home > Installshield Error > Installshield Error 6636

Installshield Error 6636

Contents

Status: This problem has been reported in the InstallShield Community Forum here and here. Status: Fixed in InstallShield 11.5 Update 1. To resolve this build warning, consider one of the following alternatives for this type of installation: • Use .spc and .pvk files instead of a .pfx file for your digital signature. Created: 2006-01-12 Macrovision tracking number: 1-CW3Y5 FIXED Setup aborts silently in CopyFile or XCopyFile when source file is missing Description: In some cases, calling CopyFile or XCopyFile when the file does http://colvertgroup.com/installshield-error/installshield-error-105.php

To resolve this error if your project does not contain any packages, use the Packages view to add a package to your project. Another example would be an entry with DWORD in it instead of dword. -6636 The file key %1 and %2 are found in the File table. Check the Knowledge Base for information about this error, or request technical support. -6619 Internal build error. It's unclear whether a fix will also be released for version 11.5. https://community.flexerasoftware.com/showthread.php?175087-HELP!-Error-6636

Isdev Error

For more information, see: • Exporting Tables from the Direct Editor • Importing Tables with the Direct Editor -7211 Building a compressed Network Image Setup.exe. Comment Submit Your Comment By clicking you are agreeing to Experts Exchange's Terms of Use. Reply With Quote 05-13-2008,11:42 PM #2 RMahil Guest Hi Meshman, This error is likely to have been caused by a duplicate mergemodule being present in your project. Workaround: The problem doesn't occur if you do not select the "Version range inclusive" option.

  1. This may cause your application failing to start.
  2. Suite/Advanced UI Projects. -7294 An Advanced UI project can include only one language.
  3. To resolve this error, consider changing the data that is described in the error message so that it uses characters from the appropriate code page.
  4. Workaround: 1.
  5. Created: 2006-01-24 Macrovision tracking number: IOC-000044312 FIXED Runtime Error 1001 when calling Installer Classes Description: When an installation attempts to call an Installer class that was built with Visual Studio 2005
  6. If a component is not configured to be 64 bit, Windows Installer may not install the component's files to the appropriate 64-bit location.
  7. An article on Macrovision's site suggested going into the component view and verifying all the paths are correct but there's only one item; primary output set to the application folder.
  8. It also may occur if the Setup.exe template is missing from the InstallShieldRedist\Language Independent\i386 folder.
  9. Therefore, the ID that you enter must not contain any characters that are invalid for file names.

For more information, see Associating a Package in an Advanced UI or Suite/Advanced UI Project with a Feature. -7239 The target file '%1' that was selected for an operation's Target setting To resolve this issue, enter a valid value in the setting that is mentioned in the warning message. Check the Knowledge Base for information about this error, or request technical support. -6593 An error occurred while initializing file class wrapper for %1. Isdev Warning Failed To Sign The Setup Launcher Workaround: Use Internet Explorer 6 on your development machine.

Do not run the action on an uninstallation. (?ComponentName=3) AND NOT($ComponentName=2) • If the custom action is sequenced after InstallFiles—Run the action only if the component will be installed locally. ($ComponentName=3) For more information, see Adding .NET Framework Redistributables to Projects. -7023 Internal build error. Ensure that it does not contain any of the following characters: \ / : * ? " < > | InstallShield uses the values that you enter for the Unique ID http://forum.installsite.net/index.php?showtopic=12290 This build error occurs if you selected Download From The Web for a package in the Packages view of an Advanced UI or Suite/Advanced UI project, but the URL setting under

An error occurred while refreshing the COM+ settings from the client machine. Installshield Internal Build Error To learn more, see Primary Packages vs. However it doesn't check for Windows Vista. Check the Knowledge Base for information about this error, or request technical support. -6574 Internal build error.

Installshield Warning

Despite having different cases, the identical key names will cause an unexpected result when the files are installed on the target system. http://www.installsite.org/pages/en/bugs_isw115.htm Note, however, that this may result in user interface issues in some scenarios because the Windows Installer does not fully support UTF-8 databases. Isdev Error J# requires the .NET Framework Redistributable Package, but it is not included in the installation. Isdev Fatal Error Created: 2006-04-25 Macrovision tracking number: 1-C2ORX Add/Remove Programs entry not deleted after uninstall with x64 application Description: After uninstalling a x64 application, the files are removed but the entry in Add/Remove

Workaround: Uninstalling security updates MS05-052 and/or MS05-054 for Internet Explorer seems to fix the problem. news Check the Knowledge Base for information about this error, or request technical support. -6596 An error occurred while attempting to sequence the action %1 in the upgraded image. If you use the Permissions setting for a service, and the settings under it, you are configuring the MsiLockPermissionsEx table of the package. Check the Knowledge Base for information about this error, or request technical support. -6602 An error occurred while attempting to close the upgraded image %1. The Language Is Missing From This Project But Included In This Release

Workaround: Check for the existence of the file before calling the CopyFile function using: Is(FILE_EXISTS, szFile) Status: This bug has been confirmed in the InstallShield Community Forum. share|improve this answer edited Mar 5 at 21:05 answered Feb 27 at 7:22 Jazimov 2,53421321 add a comment| Your Answer draft saved draft discarded Sign up or log in Sign Click here to get the free tool. have a peek at these guys The component '%2' will not be installed on the target system.

All sorted now. Installshield Download The time now is 05:57 PM. -- Desktop -- Default Mobile Style Archive Service-Level Agreement Top Stay Connected RSS YouTube Twitter LinkedIn Xing Weibo What We Do Software License Optimization Application Select "Build " from the Build menu to build a complete .msi file. -6654 The file %1 is not the key file of component %2.

Created: 2006-01-12 Macrovision tracking number: IOC-000044917 FIXED IN IS12 CopyFile crashes the setup if source file is missing Description: If you call CopyFile like this: nErr = CopyFile(szPathAndFileSource,szPathAndFileDestination); and the source

Created: 2006-05-16 Wrong Version Information in Self-Extracting Setup.exe Description: The version information for the InstallScript self-extracting executable file is not updated appropriately based on the Version setting in the Product Properties I checked the component under dependancies and I'm getting tons of these: ISDEV : warning -5061: The filename "C:\Source.Net\ProjectManager\ProjectManager\Setup1\Setup1\Default Configuration\Release\DiskImages\DISK1\program files\Business Objects\Common\3.5\bin\x3dvmchs.dll" already exists. Worked a treat!” Quintin- 1 Month Ago “Thanks for sharing, I no longer have to put up with the dreaded Installshield Error 6636” Lowell- 2 Months Ago “Will this work with Close all applications and try again.

Check the Knowledge Base for information about this error, or request technical support. -6632 Internal build error. This format neither builds nor installs correctly when included as a Component's REG File To Merge At Build. Cause: Changing REGDB_OPTIONS to access the 64 bit section in Maintenance will cause the UninstallKey (and any other 32 bit key written by the installer) to remain behind. http://colvertgroup.com/installshield-error/installshield-error-1.php This is an unnecessary duplication of these files.

If you include a sideloading app package (.appx) in a Suite/Advanced UI project but do not specify a certificate file for the package in the Certificate File setting in the Packages Created: 2006-05-16 Macrovision tracking number: 1-1CI4YR Error 1001.InstallUtilLib.dll: Unknown error when using the Stand Alone Build Tool Description: If you build a project that contains an Installer Class custom action using C:\Program Files\Macrovision\IS12\IsDev.exe\-5061 but there looks like a setup.exe there. Created: 2006-05-16 FIXED IN IS12 Registry Key's Default Value Data Missing when Merging .REG File Description: A registry key's default value data is not captured when merging a REG file during

Created: 2006-03-29 Macrovision tracking number: IOC-000044584 FIXED IN IS12 Error with MDAC Merge Module on Windows Vista Description: Running a setup that includes the MDAC 2.6 or 2.7 merge module on Error: %2 Error Description: %3 Check the Knowledge Base for information about this error, or request technical support. -6641 Internal build error. Cause: The MSBuild itself in the Microsoft.Common.targets uses a converted name like "CompanyName_ModuleName" instead the project name with period. End users can perform either of the following workarounds: Uninstall any of the three installed components through Add or Remove Programs.

Check the Knowledge Base for information about this error, or request technical support. -6613 Internal build error. Check the Knowledge Base for information about this error, or request technical support. -6622 Internal build error. This argument is required for all versions of .NET after 1.0. Check the Knowledge Base for information about this error, or request technical support. -7030 An error occurred while loading the releases that need to be built.

If you are using InstallShield in evaluation mode (that is, you have not activated it), you can build compressed Setup.exe files, but no other release types. Check the Knowledge Base for information about this error, or request technical support. -7011 %1 must have a strong name to be installed to the GlobalAssemblyCache. To learn more about digital signing, see Digital Signing and Security. -7256 To digitally sign a software identification tag file, .NET Framework 3.5 must be installed. If possible, shorten the company name or the application name, or reduce the number of platforms and/or processors that your installation supports.

Created: 2006-03-31 Macrovision tracking number: IOC-000046694 FIXED Error -5003 during setup initialization with One-Click Installs (OCI) Description: After installing Update 4 for InstallShield 11.5, InstallScript projects built as One-Click Installations (OCI)